Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Modelo: SPS120VDC40000W-2-27
Marca: APM
Lugar De Origen: Porcelana
Output Current Range: 0~400A
Input Voltage: 190~265VAC
Input Frequency: 47~63Hz
Input Power Max: 47.5KW
Power Factor: ≥0.98
Output Voltage Range: 0~120V
Output Power Range: 0~40000W
Height: 27U
Warranty: 2 years
Paquete: Cartón
productividad: other
transporte: Air
Lugar de origen: PORCELANA
Apoyo sobre: other
Certificados : CE
HS-Code: 8504401990
Hafen: DHL
Tipo de Pago: T/T
Incoterm: EXW
Este sistema de suministro de alimentación de CC de 20U alta Cuenta con configuraciones de voltaje, corriente y protección programables junto con mediciones de alta precisión. Las funciones y características son accesibles y configurables a partir de una variedad de métodos de control . La corriente de salida es de hasta 400 A MAX al conectar la unidad única interna en paralelo.
Hay más modelos, sistema de origen de DC de 40V, sistema fuente de 75V CC, sistema fuente de 150V DC, sistema fuente de 200V CC, sistema fuente de 600V CC, sistema fuente de 800V CC para su referencia.
Área de aplicación :
Esta serie es aplicable a múltiples sectores, como sectores eléctrico, iluminación y de aviación, y también podría aplicarse a la prueba de producción de Enterprise.
Características del producto:
● Con capacidad precisa de medición de voltaje y corriente.
● Paya codificada, teclado multifunción.
● Las interfaces de comunicación RS232/RS485/USB estándar, LAN y GPIB son opcionales.
● Compensación de gota de voltaje de línea de detección remota.
● EQUIPS con la función de edición de forma de onda de la lista.
● Use los comandos estándar para el protocolo de comunicación de instrumentación programable (SCPI).
● Han obtenido la certificación CE.
Especificación técnica:
ltem | MODEL | SYS120VDC40000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 250A | |
5 | Input Power Max | 47.5kW | |
6 |
Power Factor at 220VAC Input ,Full Load |
0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~120V | |
9 | Output Current | 0~400A | |
10 | Output Power | 40kW Max | |
11 | Load Regulation | Voltage | 400mV |
12 | Current | 0.4A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~120V |
16 | Resolution | 1mV | |
17 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
18 | Current Setting | Range | 0~400A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 160mVp-p/30mVrms |
22 | Current | 300mA(Full Range),50mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~120V |
24 | Resolution | 1mV | |
25 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc |
|
26 | Current Setting | Range | 0~400A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~1200V | |
30 | Output Current | 0~40A | |
31 | Output Power | 40kW Max | |
32 | Load Regulation | Voltage | 400mV |
33 | Current | 0.4A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~1200V |
37 | Resolution | 0.1V | |
38 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
39 | Current Setting | Range | 0~40A |
40 | Resolution | 0.1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 400mVp-p/75mVrms |
43 | Current | 120mA(Full Range),20mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~1200V |
45 | Resolution | 10mV | |
46 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
47 | Current Setting | Range | 0~40A |
48 | Resolution | 0.1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232(Standard); LAN,GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*1524.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*1700.0*820.0 mm | |
67 | Unit Net Weight | 120.0kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 200.0kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
*FS representa el valor máximo del rango de salida.
* N significa el número de unidades de fuente de alimentación instaladas, y N es mayor que 1.
PRODUCTOS POR GRUPO : Sistema fuente de DC > Sistema fuente de DC de 120 V
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.